Rinnai R75LSI, R98LSI-ASME, R94LSI, R50LSI Installation Instructions, General Instructions

Models: R50LSI R94LSI R75LSI R98LSI-ASME R98LSI

1 44
Download 44 pages 55.29 Kb
Page 17
Image 17
Installation Instructions

Installation Instructions

Only properly trained and qualified installers should install this appliance. The warranty may be voided due to improper installation or installation by a non- qualified installer.

Rinnai highly recommends all installers attend a product knowledge class.

For information on a Rinnai Training Course or for questions on installation call 1-800-621-9419.

R50LSi

REU-VA2019FFUD

R75LSi

REU-VA2528FFUD(A)

R94LSi

REU-VA2535FFUD

R98LSi

REU-VA3237FFU

R98LSi-ASME

REU-VA3237FFU-ASME

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

This appliance must be installed by a state qualified or licensed contractor. It is the responsibility of the person having the water heater installed to ensure the installing contractor has proper licenses and permits for installing water heaters in your location. Rinnai highly recommends that installers attend a product knowledge class to ensure customer satisfaction and warranty coverage. Failure to comply with state and local codes pertaining to water heater installations may void the warranty.

This appliance is not to be installed outdoors.

A qualified installer or service technician should install the appliance, inspect it, and leak test it before use.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa) (13.84 in W.C.).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).

Follow the installation instructions and those in Care and Maintenance for adequate combustion and ventilation air.

The appliance should be located in an area where water leakage of the unit or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.

The flow of combustion and ventilation air shall not be obstructed.

This appliance is not suitable for use in an application such as a pool or spa heater that uses chemically treated water . (This appliance is suitable for filling large or whirlpool bath tubs with potable water.)

If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing inspector on how to control thermal expansion.

Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

Keep the air intake location free of chemicals such as chlorine or bleach that produce fumes. These fumes can damage components and reduce the life of your appliance.

VA Series Indoor LS Manual

17

Page 17
Image 17
Rinnai R75LSI, R98LSI-ASME, R94LSI, R50LSI installation manual Installation Instructions, General Instructions