Rinnai R75LSI, R98LSI-ASME, R94LSI, R50LSI Freeze Protection Piping, Rinnai Water Heater

Models: R50LSI R94LSI R75LSI R98LSI-ASME R98LSI

1 44
Download 44 pages 55.29 Kb
Page 22
Image 22
Freeze Protection Piping

Freeze Protection Piping

Vacuum

Breaker

Rinnai

Water Heater

RinnaiManual background 3/4" Gas Connection

NOTE:

Heat trace ALL water pipe and fittings located outside home (attic, crawl space) or building structure. (ALL water pipe and fittings shown above the dashed line in the drawing.)

Gas Supply

NOTE:

ALL pipe and fittings shown below dashed line should be located inside home or building structure.

The vacuum breaker line should be located inside the building structure.

Minimum 3/4" Hot Water

Supply Line

1/2" Minimum

Normally Open

Solenoid Valve

S

3/4" Minimum

Normally Closed

Solenoid Valve

Manual backgroundS

Manual background Route to Floor Drain

Minimum 3/4"

Cold Water

Supply Line

 

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.

22

VA Series Indoor LS Manual

Page 22
Image 22
Rinnai R75LSI, R98LSI-ASME, R94LSI, R50LSI installation manual Freeze Protection Piping, Rinnai Water Heater