Rinnai T I M E R O P E R A T I O N, Model RCE-229A, To Cancel The On Timer

Models: RCE-229A

1 28
Download 28 pages 62.61 Kb
Page 16
Image 16
TO CANCEL THE ON TIMER

T I M E R O P E R A T I O N

WARNING

y

y

Ensure there are no obstacles or foreign materials directly in front of the appliance where the warm air will discharge into the room.

Ensure the appliance is not positioned where warm air discharge will blow directly on someone sleeping.

1

Press the “ON Timer” button

The “ON Timer” and “ON/Combustion” (green) indicators will light up.

A preset time will be displayed on the digital monitor.(The first time the ON Timer is preset, this time will be “8.0”) The ON Timer can be selected while the unit is in operation, or while it is off (if set during operation,

pressing the ON Timer button will stop the unit heating and the ON/Combustion indicator will change from red to green). The appliance will remain in standby mode.

2

Presetting the time

Pressing the “T” or “S” buttons alters the preset time. After 10 seconds the digital monitor will go out.

If the display has gone out:

Pressing the “T” or “S” buttons once will show the remaining time on the digital monitor.

Pressing the button more than once will alter the preset time.

3

The heater will operate after reaching the end of the preset time.

“ON/Combustion” Indicator glows red.

The heater will operate at the preset temperature selected in the system memory. The heater will automatically operate at 80°F if the preset temperature is set to “H”.

4

The heater stops automatically after 1 hour.

The”ON Timer” indicator will flash to indicate that heating is about to stop (at approximately 55 minutes). After another 5 minutes the heater will automatically stop heating and turn off completely.

The “ON Timer” indicator will continue to flash until the heater is manually operated again. The “ON/ Combustion” indicator will go out.

Pressing the ON-OFF button will turn off the ON Timer indicator.

TO CANCEL THE ON TIMER

Press the “ON Timer” button or press the “ON-OFF” button.

The setting will be cancelled and the timer indicators will go out.

The ON Timer will be cancelled if the power plug is removed from the power point, a power failure while the appliance was in standby mode, or if the ON Timer setting is cancelled. “00” will flash on the digital monitor when power is reinstated. Pressing the ON button and starting the unit will delete the “00”.