OPERATING INSTRUCTION PLATE

I N S T A L L A T I O N I N S T R U C T I O N S

OPERATING INSTRUCTION PLATE

CONVECTOR RCE-229A

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your finger to push with. Never use tools. If the button will not reactivate by touch, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

FOR YOUR SAFETY READ BEFORE OPERATING OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MANUAL VALVE TO TURN OFF GAS TO APPLIANCE

STOP! Read the safety information above on this label. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

1.Turn off all electric power to the appliance via

the ON/OFF button on the control panel. Locate manual gas valve to be found on back side of heater.

2.Turn Manual valve clockwiseManual backgroundto the full OFF position.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information above on

MANUAL VALVE

CLOSEDOPEN

this label. If you don’t smell gas, go to next step.

4.Turn Manual gas valve to the full ON position.

5.Turn on all electric power to the appliance.

6.Press ON/OFF button to “ON”.

7.Set the thermostat to desired setting.

8.Burner is lit when operation lamp glows red.

9.If operation lamp is flashing red, burner has not been lit.

10.If the appliance will not operate, follow the instructions “To turn off gas to appliance” and call your service technician or gas supplier.

Room Temperature

Display

Filter Warning Lamp

Temperature Temperature Function Ignition

Down UpLock Button

Manual backgroundManual background TO TURN OFF GAS TO APPLIANCE

1.Turn off electric power to the appliance using the ON/ OFF switch located on the control panel.

2.Turn manual valve clockwise Manual background to the full OFF position.

NOTE: The fan will continue to operate until the appliance is cool, do not turn the appliance off by unplugging it from the wall. Keep burner and control compartment clean. See installation and operating instructions accompanying heater.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause personal injury or loss of life. Refer to the owner’s information manual provided with this appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier.