Specifications

 

Model

RL75e

RL94e

 

R98LSe

 

R98LSe-ASME

 

 

 

 

 

 

 

 

 

Minimum Gas Consumption Btu/h

9,900 (NG)

 

 

19,000

 

10,300 (LPG)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Gas Consumption Btu/h

180,000

199,000

 

 

237,000

 

Hot water capacity (Min - Max) *

0.4 - 7.5 GPM

0.4 - 9.4 GPM

 

0.6 - 9.8 GPM

 

(1.5 - 28.5 L/min)

(1.5 - 35.5 L/min)

 

(2.3 - 37 L/min)

 

 

 

 

 

 

 

 

 

 

 

 

Hot water capacity (45°F rise)

6.6 GPM

7.1 GPM

 

 

8.5 GPM

 

(25.1 L/min)

(27.0 L/min)

 

 

(32 L/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default Temperature Setting (no controller)

 

120º F (49º C)

 

 

 

 

 

 

 

 

 

 

 

Temperature Controller Default Setting

 

104º F (40º C)

 

 

 

 

 

 

 

 

 

 

 

Maximum Temp Setting (commercial **)

160º F (71º C)

 

 

185º F (85º C)

 

 

 

 

 

 

 

 

 

 

Maximum Temp Setting (residential)

Selectable at 120º F (49º C) or

 

140º F (60º C)

see Temperature Ranges for more information

at 140º F (60º C)

 

 

 

 

 

 

Minimum Temperature Setting

 

98º F (37º C)

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

51 lb (23 kg)

 

 

55 lb (25 kg)

 

Efficiency

 

Energy Factor: 0.82

Energy Factor: 0.82

 

Thermal Efficiency:

83.0%

 

 

 

 

 

 

 

 

Noise level

 

 

49 dB (A)

 

 

 

Electrical

Normal

44 W

49 W

 

 

72 W

 

 

 

 

 

 

 

 

 

Standby

 

2 W

 

 

 

 

Consumption

 

 

 

 

 

Anti-frost Protection

104 W

 

 

116 W

 

 

 

 

 

By-Pass Control

 

Fixed

 

 

Electronic

 

Minimum Gas

Natural Gas

 

5.0 inch W.C.

 

 

 

Supply

Propane

 

8.0 inch W.C.

 

 

 

Maximum Gas

Natural Gas

 

10.5 inch W.C.

 

 

 

Supply

Propane

 

13.5 inch W.C.

 

 

 

Type of Appliance

Temperature controlled continuous flow gas hot water system.

Operation

 

With or without temperature controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.

 

 

 

 

 

 

Connections

 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

 

 

Direct Electronic Ignition

 

 

 

Electric Connections

Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)

Water Temperature Control

 

Simulation Feedforward and Feedback.

 

 

 

 

 

 

 

Water Supply Pressure

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)

Maximum Water Supply Pressure

 

150 PSI

 

 

 

 

 

 

 

 

 

 

 

Temperature Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

 

Energy Star Qualified

Yes

Yes

 

No

 

 

No

Certified for installation in manufactured

Yes

Yes

 

No

 

 

No

(mobile) homes

 

 

 

 

 

 

 

 

 

 

 

 

*Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

**for commercial and hydronic applications requiring higher temperatures

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.

VB Series Outdoor LS Manual

3

Page 3
Image 3
Rinnai RL75E, RL94E installation manual Specifications, RL75e RL94e R98LSe R98LSe-ASME