VB Series Outdoor LS Manual 25
Recommended Piping for Circulation Systems
Pressure Relief Valve
3/4" Ball Valve
3/4"Un ion
CheckValve
S
Pressure Regulator
Circulating Pump
Solenoid Valve
Boiler Drain Valve

KEY

Minimum3/4" Cold Water Supply Line
ElectricWater
Heater
Building
Fixtures
BuildingSupply
ExpansionTank
GasSupply
QTY
1
1

Rinnai

Water Heater

Rinnai
EquipmentLi st
Rinnai
WaterHeaters
RIK-KIT (Optional)
(3/4" Fittings Include:
2Unions, 2 Ball Valves,
2Drain Valves and
1Pressure Relief Valve.)
3/4"GasConnection
Tank WaterHeater to be Sized for
HeatLoss of Circulation Loop.
For this application:
Pump should be controlled by an Aqua-
stat, Timer or Combination Aquastat and
Timer.
Pump to be sized to maintain circulation
loop temperature.
The pump should be sized to overcome
t
he pressure loss through the tank water
heater, and supply and return plumbing.
Reference the Rinnai Hot Water System
Design Manual, Pump Sizing for Circula-
t
ion.
Pump to be of bronze or stainless
construction.
This is not an engineered drawing. It is intended only as a guide and not
as a replacement for professionally engineered project drawings.This
drawing is not intended to describe a complete system. It is up to the
contractor/engineer to determine the necessary components and
configuration of the particular system being installed.This drawing does
not imply compliance with local building code requirements. It is the
responsibility of the contractor/engineer to ensure installation is in
accordance with all local building codes. Confer with local building
officials before installation.
IMPORTANT: Connect the building
return line to the hot water supply line
as close as possible to the Rinnai Water
Heater.

NOTE:

For residential and commercial

applications, this piping arrange-

ment maintains full warranty.

NOTE:
For residential and commercial
applications, this piping arrangement
maintains full warranty.