Fan Module Specifications

Appendix A Technical Specifications

Fan Module Specifications

Table A-4

Power Specifications for DC-Power 24- and 48-Port Switches

 

 

 

 

Power Specifications

 

 

 

 

 

Maximum output power

C3KX-PWR-440WDC: 440 W

 

 

 

 

Input current

 

C3KX-PWR-440WDC: 16

– 8 A

 

 

DC input voltage

C3KX-PWR-440WDC: –36 to –72 VDC

 

 

 

Output ratings

 

C3KX-PWR-440WDC: –56 V@7.86 A

 

 

Voltage range domestic

C3KX-PWR-440WDC: –36 VDC (minimum)

 

 

–48 VDC (nominal), –72 VDC (maximum)

 

 

Voltage range international

C3KX-PWR-440WDC: –36 VDC (minimum)

 

 

–60 VDC (nominal), –72 VDC (maximum)

 

 

 

Total input BTU1

C3KX-PWR-440WDC: 1841

Btus per hour, 540 W

Total output BTU1

C3KX-PWR-440WDC: 1502

Btus per hour, 440 W

Wire gauge for ground connection

C3KX-PWR-440WDC: 12

AWG or 8 AWG

 

 

 

 

Branch circuit protection

C3KX-PWR-440WDC: 20

A

 

 

 

 

 

 

1.The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on –36 VDC.

Fan Module Specifications

Table A-5

Fan Module Environmental and Physical Specifications

 

 

Environmental Ranges

 

 

 

Operating temperature

23 to 113° F (–5 to 45° C)

 

 

Storage temperature

–40 to 158° F (–40 to 70° C)

 

 

Relative humidity

10 to 95% (noncondensing)

 

 

 

Altitude

 

Up to 10,000 ft (3049 m)

 

 

Physical Specification

 

 

 

Dimensions (H x D x W)

1.68 x 6.8 x 5.74 in. (4.27 x 17.27 x 14.58 cm)

 

 

 

Weight

 

0.24 lb. (0.1 kg)

 

 

Operating Specification

 

 

 

 

Airflow

 

60 cfm

 

 

 