Chapter 3 Power Supply and Fan Module Installation

Installing a Fan Module

1

Fan LED

3

Retainer clip

 

 

 

 

2

Exhaust vent

4

Extraction handles

 

 

 

 

Installing a Fan Module

Note There must be a fan module in both fan module slots.

Step 1 Pinch the fan release handle, and slide the fan out.

Caution You should replace a failed fan module within 5 minutes to avoid overheating the switch.

Step 2 Insert the new fan module into the fan slot, and firmly push the module) into the slot, applying pressure to the end of the module, not the extraction handles (Figure 3-18). When correctly inserted, the fan module is flush with the switch rear panel. When the fan is operating, a green LED is on in the top left corner of the fan.

Warning Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed circuitry could constitute an energy hazard. Statement 206

Figure 3-18 Inserting the Fan Module in the Switch

CONSOLE

AUX

STACK 1

RESET

 

STACK 2

S-PWR

XPS

S-PWR

AC OK

 

PS

C3

OK

 

KX-PWR-

 

715WAC

AC OK

 

PS

C3

OK

 

KX-PWR-

 

715WAC

253162

Finding the Fan Module Serial Number

If you contact Cisco Technical Assistance regarding a fan module, you need to know the fan module serial number. See Figure 3-19for the serial number location.

 

 

Catalyst 3750-X and 3560-X Switch Hardware Installation Guide

 

 

 

 

 

 

OL-19593-01

 

 

3-15

 

 

 

 

 

Page 77
Image 77
Cisco Systems 3560-X, 3750-X manual Installing a Fan Module, Finding the Fan Module Serial Number