15.6 Flue Blower

UHA STANDARD UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL

15.6 Flue Blower

Remove screws securing outlet flange to the flue adapter.

Refit in reverse order.

Remove screws securing flue blower mounting plate to vent box.

Remove screws securing mounting plate to blower.

Refit in reverse.

Use new gaskets.

Ensure sealed joints.

Ensure mounting plate orifice is clear and not obstructed.

 

UHA[X][S]

UHA[X][S]

UHA[X][S]

MODEL

150 - 175

200 - 300

350 - 400

 

 

 

 

Flue Blower P/N

90710405

90710403

90710402

 

 

 

 

IT IS IMPORTANT THAT ONLY THE CORRECT FLUE BLOWER SPECIFIED FOR EACH MODEL TYPE IS USED WHEN REPLACING THESE ITEMS.

Carry out a start-up after working on or changing an flue blower. See Page 27, Section 11.