CGTH USE AND CARE MANUAL
3.4Components Identification FIGURE 1: Components Identification
Gas Line
Manual Gas
| Nipple 3/8'' NPT |
|
|
|
|
|
|
|
|
|
|
| ||
| Vent Collar | Thermostat |
|
|
|
|
|
|
|
|
| |||
|
| Connection |
|
|
|
|
|
|
|
|
| |||
Wall Termination Plate |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Venting |
| Power |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Burner |
| Cord |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Front Fixed Hanger |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reflector |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Heat Exchanger |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Rear Movable |
|
|
|
|
|
|
|
|
|
| |||
Service Door | Hanger |
|
|
|
|
|
|
|
|
|
| |||
your | ||||||||||||||
|
|
|
|
|
|
| ||||||||
|
| This thermostat controls your overhead tube heater. Keep burner, control compartment and reflector clean. Read | ||||||||||||
|
| include checking your heater monthly. Installation, Service and Annual Inspection must be done by a contractor | ||||||||||||
|
| qualified in the installation and service of | ||||||||||||
|
| Ce thermostat commande votre radiateur. Gardez le module de contrôle et le reflécteur propres. Lisez le manuel | ||||||||||||
|
| d’utilisation et d’entretien | ||||||||||||
|
| notamment le contrôle mensuel du radiateur. L’installation, l'entretien et l’inspection annuelle doivent être effectués | ||||||||||||
|
| par un agent agréé. Veuillez nous contactez au | ||||||||||||
|
| questions ou demandes de manuel. |
|
|
|
|
|
|
|
|
|
| ||
|
| WARNING |
|
|
|
|
|
|
| ATTENTION | ||||
|
|
|
|
|
| MOUNT |
|
|
|
|
| |||
|
|
|
|
| THERMOSTAT |
|
|
|
| |||||
|
|
|
|
|
| HERE |
|
|
|
|
|
| ||
|
| Fire Hazard |
|
|
|
|
|
|
|
| Risque d'incendie | |||
|
| Some objects will catch fire or |
|
|
|
|
|
|
| Certains objets placés près du | ||||
|
| explode when placed close to |
|
|
|
|
|
|
| radiateur peuvent s'enflammer ou | ||||
|
| heater. |
|
| MONTER LE |
| exploser. |
|
| |||||
|
| liquids and vapors the required |
| vapeurs inflammables à la | ||||||||||
|
| Keep all flammable objects, |
|
|
|
|
|
|
| Tenir tous les objets, iquides et | ||||
|
| safe distances away from heater. | THERMOSTAT ICI | distance de sécurité requise du | ||||||||||
|
| Keep children, clothing and |
|
|
|
|
|
|
| radiateur. |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| furniture away from the heater. |
|
|
|
|
|
|
| Surveiffer les enfants. Gardes les | ||||
|
|
|
|
|
|
|
|
|
|
|
| vêtements, les meubles loin de | ||
|
| Failure to follow these |
|
|
|
|
|
|
|
| l'appareil. |
|
| |
|
| instructions will result in death, |
|
|
|
|
|
|
|
|
|
| ||
|
| injury or property damage. |
|
|
|
|
|
|
|
| Le | |||
|
|
|
|
|
|
|
|
|
|
|
| peut causer dommage au matériel. | ||
|
|
| Required Safe Distances from Combustibles |
|
| |||||||||
|
|
| Distances de Dégagement par Rapport aux Combustibles |
|
| |||||||||
|
| Horizontal Mount |
| Model | A | B | C | D | E | F | 45° Mount |
| ||
|
| Montage Horizontal | 4 | 16 | 36 | 28 | 34 | 6 | Montage à 45° | |||||
|
|
|
|
| 4 | 18 | 48 | 30 | 34 | 6 | 24" Min. (61 cm) |
| A | |
|
|
|
|
| 4 | 20 | 48 | 32 | 36 | 6 |
| |||
Protective Grill |
|
| A |
| Modèle | A B C D E F | D |
| A | |||||
| NOTES: 1. All dimensions are from the reflector. | 11 | 41 | NOTES: | 1. Toutes les dimensions sont mesurées à partir du réflecteur. | |||||||||
|
| Rating Tag |
| B | 92 | 72 | 87 | 16 |
|
| F | |||
|
| Éttiquette de | C | 11 | 46 | 122 | 77 | 87 | 16 |
|
| |||
|
| Classement | F |
| E |
| ||||||||
|
|
| B |
| 11 | 51 | 122 | 82 | 92 | 16 |
|
|
| |
|
| 2. Black numerals are in inches. Orange numerals are in |
|
|
| 2. Les chiffres noirs sont en pouces. Les chiffres oranges | ||||||||
|
| centimeters. |
|
|
|
|
|
| sont en centimètres. |
|
| |||
|
| 3. Know your model number. Model number is found on the |
|
| 3. Vous devrez connaître le numéro de votre modèle. Il se | |||||||||
|
| rating tag. (See horizontal mount drawing for location of |
|
|
| trouve sur l’étiquette de classement. (Voir le dessin du | ||||||||
|
| rating tag). |
|
|
|
|
|
| montage horizontal pour l’emplacement de l’étiquette de | |||||
|
|
|
|
|
|
|
|
|
| classement). |
|
|
| |
|
| © |
|
|
| Printed in U.S.A./Imprimé aux | P/N | 91037903 Rev F |
Burner - Contains the electrical components (i.e. blower motor, power transformer, etc.) and gas distri- bution components (i.e. gas valve, etc.) that make the heater work. There are no owner serviceable items contained in this box.
Front Fixed Hanger - Provides rigid support and mounting surface for the reflector. Holes are provided in the upper corners of the bulkhead to accommo- date suspension hardware required for installation of the heater.
Reflector - The reflector is made from formed alumi- num and reflects the radiant energy downward, bath- ing people and objects below.
Heat Exchanger - A
Rear Movable Hanger - Provides support for the tube and reflector at the end that is furthest from the burner. The support may be moved (within limits) to accom- modate hanging of the unit.
Service Door - To be removed only by a contractor qualified in the installation and service of
and gas distribution components.
Gas Line - Must only be installed and serviced by a licensed contractor or gas fitter.
Wall Termination Plate - Placed on the outside wall over the venting.
Venting - Installer must properly exhaust the heater outside. The 5” outer duct carries fresh air to the burner. The 3” inner duct carries the products of com- bustion to the outside.
Thermostat - 24 Volt Thermostat mounted with Safety Tag.
Protective Grille - Included with select models. See Page 13, Section 5.2 for details.
Vent Collar - Accommodates a 5" (125 mm) diame- ter combustion air inlet duct that delivers fresh air to the burner. The fresh air enters the burner through the twelve equally spaced holes shown above. The 3" (80 mm) diameter hole in the center of the flue col- lar accommodates the venting duct that carries the products of combustion to be vented outdoors.
4