SECTION 4: SPECIFICATIONS
4.3 General Technical Data Table
Model
CTUA With Axial Fan
Total Electrical Load | W | 210 | 210 | 210 | 210 | 415 | 415 | 510 | 510 | 745 | 745 |
|
|
|
|
|
|
|
|
|
|
|
|
Run Current | A | 1.0 | 1.0 | 1.0 | 1.0 | 1.72 | 1.72 | 1.9 | 1.9 | 3.2 | 3.2 |
|
|
|
|
|
|
|
|
|
|
|
|
Start Current | A | 1.4 | 1.4 | 1.4 | 1.4 | 2.4 | 2.4 | 2.8 | 2.8 | 4.5 | 4.5 |
|
|
|
|
|
|
|
|
|
|
|
|
Air Flow | m3/h | 3800 | 4000 | 4000 | 4000 | 5500 | 5500 | 7500 | 7500 | 11,000 | 11,000 |
|
|
|
|
|
|
|
|
|
|
|
|
Sound Pressure Level | [NR] | [51] | [51] | [51] | [51] | [52.1] | [52.1] | [52.3] | [52.3] | [52.3] | [52.3] |
at 3 m | dB(A) | 56 | 56 | 56 | 56 | 57.1 | 57.1 | 57.3 | 57.3 | 57.3 | 57.3 |
|
|
|
|
|
|
|
|
|
|
|
|
CTUB with Centrifugal Fan and CTUC Range with Centrifugal Fan and Duct Inlet |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
Total Electrical Load | W | 550 | 550 | 550 | 550 | 1100 | 1100 | 1100 | 1100 | 1650 | 1650 |
|
|
|
|
|
|
|
|
|
|
|
|
Normal Run Current | A | 4.6 | 4.6 | 4.6 | 4.6 | 11.0 | 11.0 | 11.0 | 11.0 | 15.6 | 15.6 |
|
|
|
|
|
|
|
|
|
|
|
|
Normal Start Current | A | 9.0 | 9.0 | 9.0 | 9.0 | 13.5 | 13.5 | 13.5 | 13.5 | 19.2 | 19.2 |
|
|
|
|
|
|
|
|
|
|
|
|
Normal Speed |
| Medium | Medium | Medium | Medium | Medium | Medium | Medium | Medium | Medium | Medium |
|
|
|
|
|
|
|
|
|
|
|
|
High Run Current | A | 5.5 | 5.5 | 5.5 | 5.5 | 14.0 | 14.0 | 14.0 | 14.0 | 21.0 | 21.0 |
|
|
|
|
|
|
|
|
|
|
|
|
High Start Current | A | 13.6 | 13.6 | 13.6 | 13.6 | 17.2 | 17.2 | 17.2 | 17.2 | 25.8 | 25.8 |
|
|
|
|
|
|
|
|
|
|
|
|
Air Flow | m3/h | 3300 | 3300 | 3300 | 3300 | 5500 | 5500 | 6400 | 6400 | 9400 | 9400 |
|
|
|
|
|
|
|
|
|
|
|
|
Sound Pressure Level | [NR] | [59] | [59] | [59] | [59] | [61] | [61] | [62] | [62] | [63] | [63] |
at 3 m | dB(A) | 59.5 | 59.5 | 59.5 | 59.5 | 61.5 | 61.5 | 61.8 | 61.8 | 64.2 | 64.2 |
|
|
|
|
|
|
|
|
|
|
|
|
CTUD Duct Heater with No Fan |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
**Minimun Air Flow |
|
|
|
|
|
|
|
|
|
|
|
Required | m3/h | 3300 | 3300 | 3300 | 3300 | 5500 | 5500 | 6400 | 6400 | 9400 | 9400 |
|
|
|
|
|
|
|
|
|
|
|
|
Pressure Loss Across |
|
|
|
|
|
|
|
|
|
|
|
Heat Exchanger | Pa | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
|
|
|
|
|
|
|
|
|
|
|
|
Flue and AIr Intake |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Flue and Air Intake |
|
|
|
|
|
|
|
|
|
|
|
Size | mm Ø | 100 | 100 | 100 | 100 | 100 | 100 | 130 | 130 | 130 | 130 |
|
|
|
|
|
|
|
|
|
|
|
|
*Maximum Straight |
|
|
|
|
|
|
|
|
|
|
|
Flue/Air Intake | m | 7 | 8 | 8 | 10 | 13 | 15 | 15 | 17 | 20 | 20 |
|
|
|
|
|
|
|
|
|
|
|
|
Electrical load at 230 V 50 Hz measured by calculating from total run current of appliance.
*Do not exceed the maximum length of flue stated or heater may not operate properly. Reduce the maximum length stated by 1 m for each 90° bend installed.
**If minimum air flow requirements are not met, then temperature limit devices will shut down the heater.
7