16.3 Ignition Electrode and Flame Probe

SECTION 16: REMOVAL AND REPLACEMENT PARTS

16.3 Ignition Electrode and Flame Probe

Burners

Flame

Probe

Remove all

burner compartment screws to remove

the burner

compartment and

access the

“Front View”.

Burner Compartment

Front Views

Ignition

Electrode

.120

(3 mm)

spark

gap

Burners

Thermostat

Limit

Thermodisc

Flame Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Probe

Remove

Screw

Manual background Ignition

Electrode

To replace the ignition electrode or flame probe, remove the electrical lead and screw. Pull out from mounting. Refit in reverse ensuring that the gap to burner is as shown in the front view of the burner compartment.

Description

Part Number

Spark Electrode

90427411

Automatic Ignition Flame Probe

90439300

Burners (all models except CTU-40)

92000000

Burners - CTU-40

92000001