Level Setting the BLT

Level Setting the BLT

 

 

 

 

 

 

 

 

 

R

 

 

AUD

 

 

CLOCK

AUTO

 

ILLUM

SEL

 

 

DISC

ST

Ch

DSPL

P.SCN

 

LOUD

 

 

VOL

AMFM

LD RDM RPT

 

 

 

 

TUNE

 

PWR

 

D.SCN SCAN

RPT

RDM

DIM

 

 

 

 

PAUSE

 

 

 

 

1

2

3

4

5

6

 

1kHz Test Tone @ “0dB”

 

 

 

 

 

 

9.3

 

 

 

 

 

 

 

 

 

VAC

 

 

®

 

 

 

 

®

 

 

 

 

 

 

 

 

 

 

 

 

 

BALANCED LINE TRANSMITTER

 

 

 

 

 

 

L

 

R

 

+

 

 

L

 

 

 

 

 

 

R

 

 

 

 

 

AO

DP

VE

AR

A N T C I E O

D N

Disconnect Speaker(s) from the 50.2

CD Software used to set levels is a test tone of 1kHz at “0dB” or “All Bits High”

Source Unit set to 3/4 volume (or maximum unclipped output)

Remove BLT Cover to access test pads and gain pots

AC Voltmeter set to AC Volts

AC Voltmeter “–” connected to RCA shield of BLT

AC Voltmeter “+” connected to test pad inside the BLT

Adjust BLT Gain from 2.9 VRMS min. to 9.3 VRMS max per test pad (see chart below) Be sure the time index reads greater than 30 seconds on source unit.

 

Gain Overlap

BLT Output (AC Volts)

Performance Characteristics

 

 

 

 

 

 

 

 

 

+0dB*

2.9 VRMS

Best S/N Ratio, Reduced SPL

 

 

 

 

(Used for Optimum Sound Quality)

 

 

 

 

 

 

 

+5dB

5.2 VRMS

Good S/N Ratio & SPL

 

 

 

 

(Use for Audiophile Listener)

 

 

 

 

 

 

 

+10dB

9.3 VRMS

Best Compromise between S/N Ratio & SPL

 

 

 

 

(Used for Average Listener)

 

 

 

 

 

 

 

 

 

 

 

*Absence of gain overlap will reduce SPL and may not permit amplifier to reach full output power due to various CD software.