Receptacle wiring

See the chart on page 8 for minimum gauge for receptacle wiring. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe the National Electrical Code and all local governing codes and ordinances.

Electrical requirements

See the chart on page 8 for the voltage and amperes neces- sary for this appliance. Use a time-delay fuse or time-delay circuit breaker. It is required that a separate circuit, serving only this appliance, be provided.

Electrical connection

Electrical ground is required on this appliance.

Grounding method

For your personal safety, this appliance must be grounded. This air conditioner is equipped with a power supply cord containing a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong grounding-type wall receptacle, grounded in accordance with the National Electrical Code (ANSI/NFPA 704atest edition) and all local codes and ordinances. If a mating wall receptacle is not available, it is the responsibility of the consumer to have a proper wall receptacle installed by a qualified electrician.

 

 

 

 

 

 

 

 

ALAMBRE

ENCHUFE

REQUERIMIENTOS

 

 

 

 

DE COBRE

3

l

230 voltios

(207

min.-253

m8x.)

o

Calibre

12

 

l

230/206 voltios

(197,6

min.-253

max.)

 

 

 

l

O-l 6 amperes

 

 

 

 

 

 

 

l Disyuntor

o fusible de

accibn

 

 

 

 

 

retardada

de 20 amp.

 

 

 

 

 

4

l

230 voltios

(207

min.-253

m&x.)

o

Calibre

10

l

230/206 voltios (197,6 min.-253

m&x.)

 

l

O-24 amperes

 

 

 

 

 

 

 

l Disyuntor

o fusible de

acci6n

 

 

 

 

 

retardada

de 30 amp.

 

 

 

 

 

Alambrado del tomacorriente

Ver en la tabla de la pagina 8 el calibre minim0 para el alambrado del tomacorriente. Usar alambre de cobre solamente. Es la responsabilidad del consumidor proveer alambrado del tomacorriente adecuado y apropiado, instalado por un electricista calificado. Cumplir el Codigo National de Electricidad y todos 10s codigos y reglamentos locales vigentes.

Requerimientos elhctricos

Ver en la tabla de la pAgina 8 el voltaje y amperes necesarios para este artefacto. Usar un fusible de action retardada o disyuntor de action retardada. Se requiere que se provea un circuit0 separado para ser usado por este artefacto solamente.

Conexi6n ekctrica

Este artefacto debe ser puesto a tierra.

M6todo recomendado para la puesta a tierra

Para su seguridad personal este artefacto debe ser puesto a tierra. El acondicionador de aire esta equipado con un cable electric0 provisto de un enchufe de puesta a tierra de tres clavijas. Para reducir a un minim0 el riesgo de choque, el cable debe ser enchufado en un tomacorriente mural de tres

clavijas, puesto a tierra de acuerdo con la ljltima edicih del

Codigo National de Electricidad (ANSI/NFPA 70) y todos 10s codigos y reglamentos locales. Si no se dispone de un tomacorriente mural adecuado, es la responsabilidad del consumidor hater instalar un tomacorriente mural adecuado por un electricista calificado.

10

Page 10
Image 10
Roper Air Conditioner manual Receptacle wiring, Electrical requirements, Electrical connection, Alambrado del tomacorriente

Air Conditioner specifications

Roper air conditioners are a popular choice for those seeking reliable cooling systems for their homes or offices. Known for their affordability and efficiency, Roper offers a range of products that cater to diverse cooling needs. These air conditioners come with various features designed to enhance comfort while being easy to operate and maintain.

One of the standout features of Roper air conditioners is their energy efficiency. Many models are equipped with energy-saving technology, allowing users to keep energy costs low while maintaining a comfortable indoor climate. The Energy Efficiency Ratio (EER) ratings of Roper units are designed to comply with modern standards, making them an eco-friendly option for consumers conscious of their environmental impact.

Roper air conditioners also prioritize user-friendliness. Most models are equipped with simple control interfaces, allowing users to easily adjust temperature settings, fan speed, and mode of operation. Some advanced models even incorporate programmable timers, enabling homeowners to set cooling schedules that align with their daily routines, further optimizing energy consumption.

In terms of technologies, Roper air conditioners often feature advanced cooling systems with multiple speed settings. This allows for customizable airflow, ensuring that users can achieve their desired level of comfort. Additionally, many models are designed with a dehumidification function, which helps to remove excess moisture from the air, creating a more pleasant indoor environment.

Another characteristic that makes Roper air conditioners stand out is their compact and portable designs. Many units are designed for window installation or can be used as portable air conditioners, giving users flexibility in placement and operation. This makes them an ideal solution for apartments or spaces where traditional central air conditioning systems may be impractical.

Furthermore, Roper air conditioners often come with easy-to-clean filters, promoting better air quality by reducing dust and allergens in the home. Regular maintenance is straightforward, enabling users to keep their units running efficiently over a longer period.

In conclusion, Roper air conditioners are an excellent choice for those looking for cost-effective and efficient cooling solutions. With their focus on energy efficiency, user-friendly design, advanced cooling technologies, and compact features, Roper air conditioners provide comfort and convenience for any setting. Whether for home use or office environments, Roper stands as a reliable option in the competitive air conditioning market.