Step 5. Installing the Optional Heat-Zone Kit

NOTE: There must be NO INSULATION or other com- bustibles inside the framed firestop opening.

Step 6. The Gas Control Systems

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

HEAT-ZONE

ATTACHES

HERE

Figure 32.

Two types of gas control systems are used with these models: Standing Pilot Ignition and Intermittent Pilot Ignition (IPI).

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

!WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

Intermittent Pilot Ignition (IPI) System

This system includes a 3V control valve, electronic module and intermittent pilot.

!WARNING: CONTINUOUS 110-120 VAC SER-

VICE MUST BE WIRED DIRECTLY TO THE FIRE- PLACE JUNCTION BOX.

1. Remove the knockout from the fireplace and discard it

 

 

(see Figure 32).

STANDING PILOT

 

2. Center the duct collar around the exposed hole and at-

 

 

 

tach it to the fireplace with 3 screws. NOTE: Do this BE-

 

 

FORE final positioning of the fireplace.

 

 

3. Determine the location for the air register/fan housing

 

 

assembly.

 

 

Reference the Heat-Zone kit instructions for the remaining

 

 

installation steps.

 

 

 

INTERMITTENT PILOT IGNITION

 

 

FLAME SENSOR

 

 

ROD

 

 

Figure 33. Gas Controls Systems

 

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05