Step 2. Framing the Fireplace

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommo- date wall coverings and fireplace facing material. The dia- gram below shows framing reference dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING.

Shows center of 10” x 12” vent framing holes for top and rear venting. The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe.

B

A.

.............

42”*

B.

......... 38

1/2”

C.

...............

22”

D.

......... 42

3/4”

E.

......... 27

7/8”

Framing should be constructed of 2 X 4 lumber or heavier.

E

D

C

 

A

1/2” CLEARANCE FROM BACK OF FIREPLACE TO COMBUSTIBLE

1/2” CLEARANCE FROM BOTH SIDES OF FIREPLACE TO COMBUSTIBLE

FRAMING

MEMBER

0” CLEARANCE

0” CLEARANCE TO

FRAMING MEMBER

Figure 3. Framing Dimensions

12

Hearth & Home Technologies • 6000BE, 6000BE-IPI2024-900 Rev. G • 11/05

Page 12