20 Hearth & Home Technologies • 6000BE, 6000BE-IPI • 2024-900 Rev. G • 11/05
VENTING WITH THREE (3) 90° ELBOWS
V (FT.) H (FT.)
1' MIN. (305mm) 5' MAX. (1.52m)
2' MIN. (610mm) 10' MAX. (3.1m)
3' MIN. (914mm) 15' MAX. (4.65m)
4' MIN. (1.22m) 20' MAX. (6.2m)
NOTE: H + H1 = 20' MAX. (6.2m)
V + V1 + H + H1= 40' MAX. (12.4m)
V + V1 (FT.) H + H1 (FT.)
1' MIN. (305mm) 5' MAX. (1.52m)
2' MIN. (610mm) 10' MAX. (3.1m)
3' MIN. (914mm) 15' MAX. (4.65m)
4' MIN. (1.22m) 20' MAX. (6.2m)
H +H1 = 20' MAX. (6.2m)
NOTE: V+V1+H +H1 = 40' MAX. (12.4m)
Figure 17. Venting with three 90° elbows
V
H
H
1
V
1
V
H
H
1
V
1