Roper FGS397X Before You Call For Service, Oven will not operate Burner fails to light, Check If

Models: FGS397X

1 16
Download 16 pages 36.37 Kb
Page 14
Image 14
Before You Call For Service

Before You Call For Service

If you are having an operating problem, check the chart to see what the cause might be before you call for assistance.

OPERATING PROBLEM Nothing operates.

Oven will not operate.

Burner fails to light.

Burner flames are uneven.

Burner flames lift off ports, are yellow, or are noisy when turned off.

LI;~F

popping noise

CHECK IF

mRange is properly connected to gas and electrical supplies.

. Your home’s main fuse has blown or circuit breaker has tripped

. Control knob is set in the correct position.

. The flow of combustion and/or ventilation air to the range is blocked.

. The electronic controls are set cor- rectly. Seepages 4-7.

. You have programmed a delay start time.

. Range is connected to electrical power.

. Your home’s main fuse has blown or circuit breaker has tripped.

. Burner ports are clogged.

. Burner ports are clogged.

.Bumer is wet from washing.

WHATTOJIO

n Contact an authorized Rope? service techni- cian to reconnect range to gas and/or electri- cal supply. (SeeInstallation Instructions.)

I Replace fuse or reset circuit breaker. In case of prolonged power failme, manually light burners (see page 4).

I Set control knob correctly, if needed.

n Removeblockage to airflow to and around range.

. Reset controls, if necessary.

n Contact an authorized RopeP service techni- cian to reconnect range to electrical supply. (SeeInstallation Instructions.)

n Replacefuse or reset circuit breaker. In case of prolonged power failure, manually light burners (see page 4).

n Clean with a cotton swab, soft cloth, or medium- to stiff-bristle tooth brush (seepage: 9 and 12).

. Clean with a cotton swab, soft cloth, or medium- to stiff-bristle tooth brush (see page! 9 and 12). If this fails, call an authorized RopeP service technician for service.

n Contact an authorized Rope? service techni- cian to check air/gas mixture.

. Let dry.