22 ULTRAVIEW REMOTE 2 INSTALLATIO N AND OPERATIONS MANUAL
Configure System
Figure 13. Configure system menu
To configure the local keyboard or mouse type, use the up/do wn arrow keys and select keyboard or mouse and
press enter. A display box will appear listing the choices f or the keyboard or mouse. Use the up/down arrow keys to
select the correct keyboard or mouse and press enter. T he select choices are:
Keyboard choices
Mouse choices
NOTE: A serial mouse can not
be connected to the locally,
only a PS/2 type mouse
101/102
PS/2 or PS/2 wheel
104/105
Serial 2-button (N/A)
Serial 3-button (N/A)
Expansion
If your system consists of cascaded units, the expansion sec tion of the Configure System menu must be properly
configured to provide the needed information to manage the s lave units.
It is recommended that all slave units have the same num ber of CPU ports as the “Master” unit. To change the
“Maximum computers”, “Expansion width”, and “Expansion u nits”, use the up/down arrow keys and select the item
and press enter. An input box will display for a new valu e. (See figure 5)
Maximum computers This setting configures the total number of computers that are connected and provides a wrap around value for
scanning. Switching commands are validated against this val ue for a valid port number. The “Maximum computers”
value is the Expansion width value times the number of s lave units plus the CPU ports on the master unit that are not
used for expansion. Enter the number of connected com puters and press enter. Valid entries are 2 to 256.
Expansion width The “Expansion width” setting determines how many com puters are connected to a slave unit. If the slave units are
4 port units, the width value would be 4. If they are 8 por t units, the expansion width value would be 8. If the
expansion units are a mixture of 4, 8, and/or 16 port units , the “Expansion width” value is the number of CPU ports
on the expansion unit with the greatest number of ports.
Expansion units The “Expansion units” setting is the number of slave units that are connected to the master unit. This value
determines which computer number is associated with which physical connector.
If no expansion units are used, this number should be set to zero.