Chapter 9 - Using Ethernet And RMON Statistics
Startup Alarm
The alarm that may be sent after the first measurement period. If the first sample
is greater than or equal to the rising threshold and Startup Alarm is equal to
“rising” or “risingOrFalling”, then a rising alarm will be generated. If the first is
less than or equal to the falling threshold and Startup Alarm is equal to “falling” or
“risingOrFalling”, then a falling alarm will be generated.
Rising Event
The index of the RMON Events Table entry that is used when a rising threshold is
crossed. If this value is zero or if there is no corresponding entry in the RMON
Events Table, then no alarm will be generated.
Falling Event
The index of the RMON Events Table entry that is used when a falling threshold
is reached. If this value is zero or if there is no corresponding entry in the RMON
Events Table, then no alarm will be generated.
Owner
A field describing the person who configured this record and any applicable
contact information. The RMON specification recommends that the string always
start with the word “monitor”.