Chapter 8 – Diagnostics
Each alarm has an associated description string. The string will include a port
number if it is relevant. The description may also provide an indication of the
recent rate at which this alarm is occurring (if the alarm has occurred previously).

Alarms And The Critical Failure Relay

All active alarms will immediately de-energize the critical fail relay (thus signifying
a problem). The relay will be re-energized when the last outstanding active alarm
is cleared.
Viewing And Clearing Alarms

Viewing Alarms

The Alarms Menu is available from the Diagnostics menu View Alarms command.
Alarms are displayed in the order in which they occurred, even if the real time
clock was incorrect at the time of the alarm.
Figure 48: Alarms Menu
My Switch Alarms 6 ALARMS!
Level Time Description
WARN Jan 5 17:55 Port 8 down is occurring (2 times in 192 sec)
WARN Jan 5 18:30 Port 13 down has occurred (9 times in 19 hr)
WARN Jan 5 19:10 Port 5 is down
WARN Jan 6 13:44 Port 7 down has occurred (2 times in 23 hr)
WARN Jan 6 17:40 Port 12 was down
WARN Jan 6 23:02 Port 6 is down
<CTRL> Z-Help S-Shell D-PgDn U-PgUp

Clearing Alarms

The Diagnostics menu Clear Alarms command will clear all alarms.
RuggedCom 73