RuggedCom RS900L manual Ethernet Ports, 3.1 RJ11 Ethernet over VDSL Port, Overview

Models: RS900L

1 26
Download 26 pages 62.41 Kb
Page 14
Image 14
3 Ethernet Ports

3 Ethernet Ports

3.1 RJ11 Ethernet over VDSL Port

3.1.1 Overview

The Ethernet over VDSL (EoVDSL) port on RS900L operates in pairs with one configured as the Master and the other as the Slave. In VDSL literature the terms Central Office (CO) or Line Termination (LT) are used interchangeably for the Master and the terms Customer Premise Equipment (CPE) or Network Termination (NT) are used interchangeably for the Slave. Configuration of Master or Slave mode is done through the RuggedSwitch Operating System.

The unit contains one EoVDSL data port that allows connection to Category 3 (CAT-3) unshielded twisted-pair (UTP) cable with RJ11 male connectors. The figure below shows the RJ45 port pin-out and LEDs.

Figure 9 - RJ11 port pin-out and LEDs

Pin

Signal

3

Ring

4

Tip

Table 3 - RJ11 port pin-out

Status LED

Colour

Mode

Green

Link / Act

Green

 

 

Table 4 - RJ11 port LED description

2007 RuggedCom Inc. All rights reserved

Activity

On

Off

Solid

Blinking

14

Comments

Master Mode

Slave Mode

Link Established

Tx Activity

Rev101