RuggedCom RS900L manual AC Power Supply Wiring and Grounding

Models: RS900L

1 26
Download 26 pages 62.41 Kb
Page 9
Image 9
2.2 Power Supply Wiring and Grounding

2.2 Power Supply Wiring and Grounding

2.2.1 AC Power Supply Wiring and Grounding

Figure 4 - Power Supply Inputs

The AC power supply inputs should be connected as follows:

1.+/L should be connected to AC Line/Hot.

2.-/N should be connected to AC Neutral.

3.Surge Ground should be connected to the Chassis Ground via a braided cable or other appropriate grounding wire. Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit.

4.Chassis Ground must be connected to the AC ground terminal.

NOTES:

1.Equipment must be installed according to the applicable country wiring codes.

2.All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis Ground. Note that all line-to-ground transient protection circuitry will be disabled.

 

9

2007 RuggedCom Inc. All rights reserved

Rev101

Page 9
Image 9
RuggedCom RS900L manual AC Power Supply Wiring and Grounding