5 Type Tests
5.1 IEC 61850-3 Type Tests
| Test |
| Description |
| Test Levels |
| |
|
|
|
|
|
|
|
|
| IEC |
| ESD | Enclosure Contact |
| +/- 8kV | |
|
|
|
|
|
| ||
|
| Enclosure Air |
| +/- 15kV | |||
|
|
|
|
| |||
|
|
|
|
|
|
| |
| IEC |
| Radiated RFI | Enclosure ports |
| 20 V/m | |
|
|
|
| Signal ports |
| +/- 4kV @ 2.5kHz | |
|
|
|
|
|
|
| |
| IEC |
| Burst (Fast | D.C. Power ports |
| +/- 4kV | |
|
| Transient) | A.C. Power ports |
| +/- 4kV | ||
|
|
|
| ||||
|
|
|
| Earth ground ports |
| +/- 4kV | |
|
|
|
|
|
|
| |
|
|
|
| Signal ports |
| +/- 4kV | |
|
|
|
|
| line | ||
|
|
|
|
|
| ||
| IEC |
| Surge | D.C. Power ports |
| +/- 2kV | |
|
|
| line | ||||
|
|
|
|
|
| ||
|
|
|
| A.C. Power ports |
| +/- 4kV | |
|
|
|
|
| line | ||
|
|
|
|
|
| ||
|
|
|
| Signal ports |
| 10V | |
| IEC |
| Induced | D.C Power ports |
| 10V | |
|
| (Conducted) RFI | A.C. Power ports |
| 10V | ||
|
|
|
| ||||
|
|
|
| Earth ground ports |
| 10V | |
| IEC |
| Magnetic Field | Enclosure ports |
| 40 A/m continuous, 1000 A/m for 1 s | |
|
|
|
| D.C. Power ports |
| 30% for 0.1s, 60% for 0.1s, 100% for | |
| IEC |
|
|
| 0.05s | ||
|
| Voltage Dips & |
|
| |||
|
|
|
|
| 30% for 1 period, 60% for 50 periods | ||
|
|
| Interrupts |
|
| ||
| IEC |
| A.C. Power ports |
| 100% for 5 periods, 100% for 50 | ||
|
|
|
| ||||
|
|
|
|
| periods 2 | ||
|
|
|
|
|
| ||
|
|
|
| Signal ports |
| 2.5kV common, 1kV differential mode | |
|
|
|
|
| @ 1MHz | ||
|
|
|
|
|
| ||
| IEC |
| Damped | D.C. Power ports |
| 2.5kV common, 1kV differential mode | |
|
| Oscillatory |
| @ 1MHz | |||
|
|
|
|
| |||
|
|
|
| A.C. Power ports |
| 2.5kV common, 1kV differential mode | |
|
|
|
|
| @ 1MHz | ||
|
|
|
|
|
| ||
| IEC |
| Mains Frequency | Signal ports |
| 30V Continuous, 300V for 1s | |
|
| Voltage | D.C. Power ports |
| 30V Continuous, 300V for 1s | ||
|
|
|
| ||||
| IEC |
| Ripple on D.C. | D.C. Power ports | 10% |
| |
|
| Power Supply |
| ||||
|
|
|
|
|
|
| |
|
|
|
| Signal ports |
| 2kV AC | |
| IEC |
| Dielectric Strength | D.C. Power ports |
| 2kV AC | |
|
|
|
| A.C. Power ports |
| 2kV AC | |
|
|
|
| Signal ports |
| 5kV | |
| IEC |
| H.V. Impulse | D.C. Power ports |
| 5kV | |
|
|
|
| A.C. Power ports |
| 5kV | |
|
|
|
|
|
|
|
|
Table 16 - IEC
24
2007 RuggedCom Inc. All rights reserved
Severity
Levels
4
4
x x 4 4 4
4
3
4
3
3
3
3
N/A
N/A
N/A
N/A
3
3
3
4
4
3
N/A
N/A
N/A
N/A
N/A
N/A
Rev101