RuggedCom RS900L Fiber Optic Ethernet Port Specifications, Communication Standards, Sensitivity

Models: RS900L

1 26
Download 26 pages 62.41 Kb
Page 22
Image 22
4.6 Fiber Optic Ethernet Port Specifications

4.6 Fiber Optic Ethernet Port Specifications

Speed

Standard

100Base-FX

100Base-FX

100Base-FX

100Base-FX

100Base-FX

100Base-FX

100Base-FX

Mode /

Connector

MM/ ST MM / SC MM / LC

MM / MTRJ

SM / ST SM / SC SM / LC

Tx λ

(nm)

1310

1310

1310

1310

1310

1310

1310

Cable Type2

(m)

50/125

50/125

50/125

50/125

9/125

9/125

9/125

Tx Pwr

Rx

(dBm peak) 3

Sensitivity

(Min / Max)

(dBm Average) 3

 

 

-15.7

-33.5

-16/-11

-33

-19 / -14

-32

-16/-11

-33.5

-15/-8

-32

-13/5

-31

 

 

-15/-8

-31

 

 

Rx Saturation (dBm Peak) 3

-11

-11

-14

-11

-7

-4

-5

Typical

Distance

(km) 1

2

2

2

2

20

20

15

Power

Budget

(dB)

17

17

15

17

16.5

20

16.5

Table 13 - Fiber Optic Port Specifications

NOTES:

1.Maximum segment length is dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.

4.7 Communication Standards

Protocol

Standards

Ethernet

IEEE 802.3

VDSL

ETSI TS 101 270-2 V1.1.1, ITU-T G.993.1, ANSI T1E1.4

Table 14 - Communication Standard Compliance

 

22

2007 RuggedCom Inc. All rights reserved

Rev101

Page 22
Image 22
RuggedCom RS900L Fiber Optic Ethernet Port Specifications, Communication Standards, Mm / St Mm / Sc Mm / Lc, Sensitivity