5.2 IEEE 1613 Type Tests

5.2 IEEE 1613 Type Tests

 

Test

 

 

Description

 

Test Levels

 

IEEE C37.90.3

 

ESD

 

Enclosure Contact

 

+/- 8kV

 

 

 

Enclosure Air

 

+/- 15kV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEEE C37.90.2

 

Radiated RFI

 

Enclosure ports

 

35 V/m

 

 

 

 

 

Signal ports

 

+/- 4kV @ 2.5kHz

 

IEEE C37.90.1

 

Fast Transient

 

D.C. Power ports

 

+/- 4kV

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

+/- 4kV

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports

 

+/- 4kV

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

2.5kV common mode @ 1MHz

 

IEEE C37.90.1

 

Oscillatory

 

 

 

 

 

 

 

D.C. Power ports

 

2.5kV common & differential mode @ 1MHz

 

 

 

 

 

A.C. Power ports

 

2.5kV common & differential mode @ 1MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

5 kV (Failsafe Relay)

 

IEEE C37.90

 

H.V. Impulse

 

D.C. Power ports

 

5 kV

 

 

 

 

 

A.C. Power ports

 

5 kV

 

 

 

Dielectric

 

Signal ports

 

2kV AC(Failsafe Relay)

 

IEEE C37.90

 

 

 

 

 

 

 

 

D.C. Power ports

 

2kV AC

 

 

Strength

 

 

 

 

 

 

A.C. Power ports

 

2kV AC

 

 

 

 

 

 

Table 17 - IEEE 1613 Type Tests

NOTE:

If the unit contains copper ports the IEEE 1613 conformance is Class 1 (During disturbance errors may occur but recovery is automatic).

If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 (During disturbance no errors will occur).

5.3 IEC Environmental Type Tests

Test

IEC 60068-2-1

IEC 60068-2-2

IEC 60068-2-30

IEC 60255-21-1

Description

Cold Temperature

Dry Heat

Humidity (Damp Heat,

Cyclic)

Vibration

Test Ad

Test Bd

Test Db

Tests Fc

Test Levels

-40 deg. C, 16 Hours

+85 deg. C, 16 Hours

95% (non-condensing), 55°C, 6 cycles

2g @ (10-150) Hz

Severity

Levels

N/A

N/A

N/A

Class 2

IEC 60255-21-2

Shock

Tests Ea

30g @ 11 ms

Table 18 - Environmental Type Tests

Class 2

 

25

2007 RuggedCom Inc. All rights reserved

Rev101