h- Set SSID: Ensure that WLAN Interface -> Network Parameters -> Network Name [SSID] -> RUGGEDTEST is configured.

i- Set Authentication Mode: Ensure that WLAN Interface -> Security Parameters -> Authentication Mode ->wpa2-pskis selected.

j- Set Encryption Algorithm: Ensure that WLAN Interface -> Security Parameters -> Encryption Algorithm -> aes is selected.

k- Set Passphrase [WPA,WPA2]: Ensure that WLAN Interface -> Security Parameters -> Passphrase [WPA,WPA2] -> testing1234 is configured.

l- Soft reset the wireless interface: Ensure that WLAN Interface -> Miscellaneous Parameters -> WLAN Reset -> Quick reset is selected.

m- After a ‘Quick reset’ has been executed, the RS900W unit will be configured for Client/Bridge operation with WPA2 (802.11i) security enabled. After this step, the Client/Bridge unit will associate with the similarly configured AP and a ‘ping’ test should work at this point

2.3 Configure the RS900W for “Client / IP Bridge” operation

The only difference between the configuration of “Client / IP Bridge” and “Client / Bridge” is the selection of “Operational Mode” in Section 2.2 Step (e). Instead of setting “Client Bridge” option you will set “Client IP Bridge” option in the “Operational Mode”.