RuggedCom RS969 Technical Specifications, Operating Environment, Power Supply Specifications

Models: RS969

1 31
Download 31 pages 20.22 Kb
Page 20
Image 20
Technical Specifications

3

Technical Specifications

 

3.1

Operating Environment

 

 

 

 

 

 

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85°C

Ambient Temperature as

 

 

 

measured from a 30 cm radius

 

 

 

surrounding the center of the

 

 

 

M969 enclosure.

Ambient Relative Humidity

5% to 95%

Non-condensing

Ambient Storage Temperature

-40 to 85°C

 

 

IP Rating

IP67

 

 

Operating Altitude

0 to 15240m (0 to 50000 ft)

Over temperature range of -40

 

 

 

to 85°C

3.2

Power Supply Specifications

 

Power Supply Type

12 – 24 VDC

24VDC

48VDC

HI (125/250 VDC) 1 HI (110/230 VAC) 1

Minimum

Input

10VDC

18VDC

36VDC

88VDC

85VAC

Maximum

Input

36VDC

36VDC 72VDC

300VDC

265VAC

Fuse

Rating

3.15A (T)

3.15A (T)

3.15A (T)

3.15A (T)

Isolation

1.5kV DC

1.5kV DC

1.5kV DC

4 kV AC 5.5

kV DC

Maximum Power

Consumption

10W

NOTES:

1.This is the same power supply for both AC and DC.

2.(T) denotes time-delay fuse

3.For continued protection against risk of fire, replace only with same type and rating of fuse.

3.3Failsafe Relay Specifications

Parameter

Value

 

 

Max Switching Voltage

30VAC, 80VDC

Rated Switching Current

0.3A @ 30VAC

 

1A @ 30VDC, 0.3A @ 80VDC

NOTES:

1.Resistive Load.

2.For Class-2 circuits only.

20

2008 RuggedCom Inc. All rights reserved

Rev104

Page 20
Image 20
RuggedCom RS969 manual Technical Specifications, Operating Environment, Power Supply Specifications