3

Technical Specifications

 

3.1

Operating Environment

 

 

 

 

 

 

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85°C

Ambient Temperature as

 

 

 

measured from a 30 cm radius

 

 

 

surrounding the center of the

 

 

 

M969 enclosure.

Ambient Relative Humidity

5% to 95%

Non-condensing

Ambient Storage Temperature

-40 to 85°C

 

 

IP Rating

IP67

 

 

Operating Altitude

0 to 15240m (0 to 50000 ft)

Over temperature range of -40

 

 

 

to 85°C

3.2

Power Supply Specifications

 

 

Power Supply Type

 

 

Minimum

 

 

Maximum

 

 

Fuse

 

 

 

 

Input

 

 

Input

 

 

Rating

 

 

 

 

 

 

 

 

 

 

 

12 – 24 VDC

 

10 VDC

 

36 VDC

 

3.15A (T)

 

24 VDC

 

18 VDC

 

36 VDC

 

3.15A (T)

 

48 VDC

 

36 VDC

 

72VDC

 

3.15A (T)

 

HI (125/250 VDC) 1

 

88 VDC

 

300 VDC

 

3.15A (T)

 

HI (110/230 VAC) 1

 

85 VAC

 

265 VAC

 

Isolation

1.5kV DC

1.5kV DC

1.5kV DC

4 kV AC 5.5

kV DC

Maximum Power

Consumption

10W

NOTES:

1.This is the same power supply for both AC and DC.

2.(T) denotes time-delay fuse

3.For continued protection against risk of fire, replace only with same type and rating of fuse.

3.3Failsafe Relay Specifications

Parameter

Value

 

 

Max Switching Voltage

30VAC, 80VDC

Rated Switching Current

0.3A @ 30VAC

 

1A @ 30VDC, 0.3A @ 80VDC

NOTES:

1.Resistive Load.

2.For Class-2 circuits only.

20

2008 RuggedCom Inc. All rights reserved

Rev104

Page 20
Image 20