Isolation

Comments

 

 

1500 Vrms

Dielectric test voltage (1 minute) between coil & contacts

3.4 Twisted Pair Data Port Specifications

Data Port

Media

Distance

10/100 Mbps

Cat 5 UTP or STP

100m

 

 

 

Connector Type

RJ45 or M12

3.5 Fiber Optical Port Specifications

For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optical communications. The following table details fiber optic specifications based on the order code / transceiver selected at time of ordering.

Order Code

2LCMM

2LC10

2LC25

Mode /

Connector

MM/ LC SM / LC SM / LC

Tx λ

Cable

(nm)

Type2

 

 

85050/125

1310 9/125

1310 9/125

Tx Pwr (dBm) 3 (Min/Max)

-9.5 / -4 -9.5 / -3 -5 / 0

Rx

Sensitivity

(dBm) 3

-20 -22 -22

Rx

Saturation

(dBm) 3

0 -3 -3

Typical

Distance1

(km)

0.5

10

25

Power

Budget

(dB)

13

18.5

19.5

NOTES:

1.Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.All cabling is duplex type unless otherwise specified.

3.All optical power numbers are listed as dBm averages.

21

2008 RuggedCom Inc. All rights reserved

Rev104

Page 21
Image 21
RuggedCom RS969 manual Twisted Pair Data Port Specifications, Fiber Optical Port Specifications