3. Installation Procedures

3.6.2. SFD Type Base Station

The power system is supplied by the operator.

Connect the power system DC output to the RuggedCom cable with proprietary connector (supplied by RuggedCom).

Connect the other side (open end) of the RuggedCom cable to the operator’s power system (according to the labelling on the cable and the tables below.

RuggedCom Cable

Power Supply

Note

-48VDC

-48VDC

GND

 

 

 

+48VDC

+48VDC/ GND

“HOT Line”

 

 

 

GND

-48VDC/ GND

Connect -48V and GND

 

 

 

Table 3.4. +48 VDC Power System

 

 

RuggedCom Cable

Power Supply

Note

-48VDC

-48VDC

“HOT Line”

 

 

 

+48VDC

+48VDC/ GND

GND

 

 

 

GND

+48VDC/ GND

Connect +48V and GND

 

 

 

Table 3.5. -48 VDC Power System

Figure 3.11, “Positive 48V Configuration”and Figure 3.12, “Negative 48V Configuration”show +48V and -48V configurations.

Figure 3.11. Positive 48V Configuration

Figure 3.12. Negative 48V Configuration