3-2
Connections
When starting up the projector, with the power switch or via the
stand-by key, the projector can start up in two ways if the “CRT
run in” cycle option is switched OFF.
- full white image (projector warm up) or
- immediately image display.
The way of starting up can be set in the service mode.
Start up with full white image.
The next menu will be displayed for 30 seconds.
a. Start up with warm up period.
If no action is taken, a white image will be displayed for 20 min-
utes.
This white image will be shifted on the faceplate of the CRT to
avoid burn in. During this warm up period, it is possible to interrupt
this white image projection by pressing the EXIT key. The previous
menu will be repeated for another 30 seconds but the remaining
time will be indicated.
If EXIT is pressed, the remaining warm up period will be shipped.
During the warm up period, every 30 seconds a text box with the
remaining time will be displayed on the screen for 2 seconds. This
text box will be displayed every time on another place.
If another key, different from EXIT, is pressed, a text box with fol-
lowing text will be displayed:
Please use <EXIT> to leave this procedure.
b. Start up without warm up period.
If the EXIT key is pressed, the warm up period will be skipped and
the projector is immediately ready for use.
Warning : skipping this warm up procedure can reduce the
initial picture quality of the projected image.
Signal Input Connection to the Projector:
- Composite Video
- S-Video
- RGBS or RGsB
- RGB3S or RG3sB (option)
1 Not Used
2 Not Used
3 Input signal : R-Y, Y and B-Y with separate composite sync or
with separate Hor and Vert. sync or with composite sync on Y.
4 Input signal : R, G and B with separate Tri level sync or with
Tri-level sync on green.
5 Input signal : R-Y, Y and B-Y with separate Tri level sync or
with composite Tri-level sync.
* Video or S-Video : switchable in the Picture Tuning menu.
This device complies with part 15 of
the FCC rules. Operation is subject to
following two conditions (1). This
device may not cause harmful inter-
ference, and (2) this device must
accept any interference received
including interference that may cause
undesired operation.
OffOn
Power/Mains
Comm Port Port 3 B
G
RComp/
HSYNCVSYNC Green=Oper.
Red=Stby
VIDEO
3 14 5 2
PROJECTOR WARM UP
A FULL WHITE PATTERN
WILL BE GENERATED FOR
20 MINUTES
FOR IMMEDIATE USE OF
THE PROJECTOR, PRESS
<EXIT>
WARNING: SKIPPING THIS
PROCEDURE CAN REDUCE
THE INITIAL PICTURE
QUALITY OF THE PROJECTED
IMAGE.
THIS OPTION CAN BE
DISABLED IN THE SERVICE
MENU
REMAINING
PROJECTOR
WARM UP
TIME
18.5 MIN
PLEASE USE
<EXIT> TO
LEAVE THIS
PROCEDURE
Port No. Projector Input Press Digit Button
1 Not Used Not Used
2 Not Used Not Used
3 RGB23
4/5 RGB24 or 5
4/5 Component Video36
4/5 RGB with Tri-Level Sync47
4/5 Component Video
with Tri-Level Sync58
Only available when the optional Tri-level sync module is installed.