Maintenance and Troubleshooting
5. Maintenance and Troubleshooting
The lamp should be replaced when it reaches the end of its life (typically between 2000 and 4000 hours depending on the Lamp Power setting), or sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to obtain a replacement lamp.
1.Turn off the projector and unplug the power cord. Allow the projector to cool down for approximately 60 minutes prior to removing the lamp assembly for replacement.
2.Using a
compartment cover in place.
3. Remove the rear compartment cover by tilting it upward.
5.1
Lamp Replacement
4.Loosen the screw on the lamp cover and pull the lamp cover out.
5.Loosen the two screws on the lamp module.
6.Pull the lamp module handle firmly to remove the lamp module.
7.Perform Steps 6 through 2 (in reverse order) to install the new lamp module.
8.Turn on the power and reset the lamp timer.
Runco | 61 |