Russell Hobbs RHGC1 Injector Table, Rapid Burner, Semi-Rapidburner, Auxillary Burner, Oven Burner

Models: RHGC1

1 28
Download 28 pages 27.45 Kb
Page 27
Image 27

INJECTOR TABLE

 

LPG

NG

Gas Category: II2H3+

G30

G20

 

28-30 mbar

20 mbar

 

 

 

RAPID BURNER

 

 

Injector Diameter (%mm)

85

115

Nominal Rating (kW)

3

2.75

Consumption in 1h

218.1 gr/h

 

Consumption in 1h

 

285.7 lt/h

(at 150C and 1013mbar pressure)

 

 

 

 

 

SEMI-RAPID BURNER

 

 

 

 

 

Injector Diameter (%mm)

65

97

Nominal Rating (kW)

1.75

1.75

Consumption in 1h

127.2 gr/h

 

Consumption in 1h

 

166.7 lt/h

(at 150C and 1013mbar pressure)

 

 

 

 

 

AUXILLARY BURNER

 

 

Injector Diameter (%mm)

50

72

Nominal Rating (kW)

1

1

Consumption in 1h

72.7 gr/h

 

Consumption in 1h

 

95.2 lt/h

(at 150C and 1013mbar pressure)

 

 

OVEN BURNER

 

 

Injector Diameter (%mm)

76

120

Nominal Rating (kW)

2.8

2.8

Consumption in 1h

203.6 gr/h

 

Consumption in 1h

 

266.7 lt/h

(at 150C and 1013mbar pressure)

 

 

 

 

 

GRILL BURNER

 

 

 

 

 

Injector Diameter (%mm)

68

110

Nominal Rating (kW)

2.2

2.2

Consumption in 1h

160 gr/h

 

Consumption in 1h

 

209.5 lt/h

(at 150C and 1013mbar pressure)

 

 

 

 

 

For Customer Services, Spare parts & Warranty Information please call 0845 683 8717