3.3 Adjustment of feet

3.3 Adjustment of feet

Your product stands on 4 adjustable feet. When the product is placed where it is to be used, check if the product is balanced. If it is not balanced, you can make the adjustment by turning the feet clockwise if required. It is possible to raise the appliance maximum 35mm by the feet. If the feet are adjusted do not move the appliance by dragging, it should be moved by lifting it up.

Figure 6

3.4 Gas connection

Assembly of gas supply and leakage check

The cooker should be connected to the gas-supply by a gas safe registered installer. During installation of this product it is essential to fit an approved gas tap to isolate the supply from the appliance for the convenience of any subsequent removal or servicing. Connection of the appliance to the gas mains or liquid gas must be carried out according to the prescribed regulation in force, and only after it is ascertained that it is adaptable to the type of gas to be used. You can find the information related to appropriate gas types and appropriate gas injectors on technical data table. If the pressure of used gas is different than these values stated or not stable in your area, it may be required to assemble an available pressure regulator on the gas inlet. It is certainly required to contact to the authorised service to make these adjusments.

The points that must be checked during flexible hose assembly

Connecting the gas supply

To make the connection, a flexible hose should be used corresponding to the current gas regulations which are:

the hose must never be at any point in its length in contact with the 'hot' parts of the cooker;

the hose must never be longer than 1.5 metre;

the hose must not be subject to any tension or torsional stress and it must not have any excessively narrow curves or bottlenecks;

the hose must be easy to inspect along its entire length to check its condition;

the hose must always be in good condition, never attempt to repair.

!The installation must comply with gas safety (installation and use) regulations

1984. In all cases for the above, by law, a qualified, corgi approved engineer must be called for installation.

As gas is turned on, all connection parts and hose must be checked with soapy water or leakage fluids. Do not use naked flame to check gas leakage. All metal components used during gas connection must be clear of rust. Also check the expiry dates of components to be used.

For Customer Services, Spare parts & Warranty Information please call 0845 683 8717 7