![IMPORTANT: How to wire a 13 amp plug](/images/new-backgrounds/61614/6161425x1.webp)
IMPORTANT: How to wire a 13 amp plug
The wires in the mains lead on this appliance are coloured in accordance with the following code:
• | Green and Yellow – Earth | Earth |
| |
• | Blue – Neutral | Fuse (3 Amp) | ||
Neutral (Blue) | ||||
• | Brown – Live | Live (Brown) | ||
|
| |||
|
|
| Cord Clamp | |
|
|
| Figure 8 |
As the colours may not correspond with the markings identifying the terminals in your plug proceed as follows. The green and yellow wire must be connected to the terminal in the plug, which is marked with the letter E, or with the earth symbol or coloured green and yellow. The blue wire must be connected to the terminal marked N. The brown wire must be connected to the terminal marked L.
3.6 Gas conversion
Caution : The following procedures must be undertaken by authorised service people.
Your appliance is adjusted to be operated with LPG/NG gas. The gas burners can be adapted to different types of gas, by replacing the corresponding injectors and adjusting minimum flame length suitable to the gas in use. For this purpose, following steps should be performed:
Changing injectors:
Hob Burners:
•Cut off the main gas supply and unplug from the electric mains.
•Remove the burner cap and the adapter(Figure 9).
•Unscrew the injectors. For this, use a 7mm spanner(Figure 10).
•Replace the injector with the ones from the gas conversion kit, with corresponding diameters suitable to the type of gas that is going to be used, according to the information chart (which is also supplied in the gas conversion kit).
For Customer Services, Spare parts & Warranty Information please call 0845 683 8717
9