Installing the water heater.

A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must remain in the opening provided and marked for the purpose on the water heater. No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves.

Relief Valve

The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate.

The Btuh rating of the relief valve must equal or exceed the Btuh input of the water heater as marked on its rating plate.

Position the outlet of the relief valve above a suitable open drain to eliminate potential water damage. Piping used should be of a type approved for hot water distribution.

The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line.

The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction, or reducer coupling should be installed in the discharge line.

WARNING: The tank must be full of water before heater is turned on. The water heater warranty does not cover damage or failure resulting from operation with an empty or partially empty tank.

To Fill the Water Heater

Make certain that the drain valve is closed, then open the shut-off valve in the cold water supply line.

Open each hot water faucet slowly to allow the air to vent from the water heater and piping.

A steady flow of water from the hot water faucet(s) indicates a full water heater.

Do not allow the flammable vapor sensor to become submerged in water.

Condensation

Condensation can form on the tank when it is first filled with water. Condensation might also occur with a heavy water draw and very cold inlet water temperatures.

Drops of water falling on the burner can produce a sizzling or pinging sound.

This condition is not unusual, and will disappear after the water becomes heated. If, however, the condensation continues, examine the piping and fittings for possible leaks.

NOTICE: Additional information on this subject may be found at www.rheem.com, under Rheem Water Heating, "Support", scroll down to the Technical Service Section and to Bulletins 1400 Series Section and choose Bulletin #1402..

10

Page 10
Image 10
Ruud AP14236 installation instructions Relief Valve, To Fill the Water Heater, Condensation

AP14236 specifications

Ruud AP14236 is a highly efficient air conditioning unit that stands out in the residential HVAC market for its remarkable performance and innovative technology. This model is specifically engineered to provide optimal cooling and heating solutions, offering homeowners comfort year-round while also emphasizing energy efficiency.

One of the key features of the Ruud AP14236 is its efficiency rating, showcased by its SEER (Seasonal Energy Efficiency Ratio) rating, which provides users with an indication of energy consumption versus cooling output. With ratings often exceeding 14, the unit is designed to reduce energy bills significantly while maintaining a comfortable indoor environment. In addition to SEER, the unit boasts an HSPF (Heating Season Performance Factor) that guarantees excellent performance during colder months.

The Ruud AP14236 utilizes advanced inverter technology that allows for variable speed operation. This technology enables the air conditioner to adjust its cooling output based on the actual temperature in the home, leading to lower energy consumption while ensuring that the desired climate is reached swiftly and efficiently. This feature not only enhances comfort but also prolongs the lifespan of the unit, as it does not require the constant on-off cycling seen in traditional systems.

Equipped with an enhanced filtration system, the Ruud AP14236 significantly improves indoor air quality by capturing dust, allergens, and other particulates. This characteristic is particularly advantageous for those with allergies or respiratory conditions, as it creates a healthier living environment.

Durability is another hallmark of the Ruud AP14236, featuring robust construction materials designed to withstand the rigors of varied weather conditions. The unit's cabinet is often galvanized and treated to resist rust, ensuring longevity and reducing maintenance issues.

Noise reduction is also a primary focus in the design of Ruud AP14236. The unit operates quietly, allowing for comfortable living spaces without the disruptive sounds commonly associated with air conditioning systems. This is achieved through sound-dampening technology and acoustic insulation.

In summary, the Ruud AP14236 is engineered for energy efficiency, versatility, durability, and quiet operation. Homeowners seeking a reliable and efficient air conditioning solution will find that this unit meets their needs while providing year-round comfort and improved air quality.