Ruud AP14236 installation instructions Gas Valve LED Codes

Models: AP14236

1 36
Download 36 pages 60.71 Kb
Page 32
Image 32
Gas Valve LED Codes

Gas Valve LED Codes

LED Status

Problem

 

Solution

○ ○ ▼ A B C

 

1.

Check that the earth ground connection is properly

● ○ ○ ● ○ ○

An open earth ground circuit to the

2.

connected.

 

ignition system.

Check that the ground conductor on the water

 

 

 

heater is properly connected.

○ ○ ▼ A B C

 

1.

Check proper connection of line

● ○ ● ○ ● ○

Wiring error or a high resistance to

2.

neutral and hot wires.

 

earth ground.

Check that the water heater is securely connected

 

 

 

to earth ground.

○ ○ ▼ A B C

Pressure switch remained closed

1.

Pressure switch wiring is incorrect.

● ○ ● ○ ○ ○

longer

2.

Replace pressure switch.

than 5 seconds after the call for

 

heat began.

 

 

○ ○ ▼ A B C

Pressure switch remained open lon-

1.

Pressure switch wiring is incorrect.

● ○ ● ○ ○ ●

thanger 5 seconds after the combustion

2.

Pressure switch tubing is not connected correctly.

 

blower was energized.

3. Air intake or exhaust obstructed.

○ ○ ▼ A B C

Error in the hot surface ignitor cir-

1.

Check that all wiring is correct and secure.

● ○ ● ○ ● ●

cuit.

2.

Replace hot surface ignitor.

○ ○ ▼ A B C

System in lockout.

1.

Gas supply is off or too low to operate.

● ○ ○ ● ● ○

 

2.

Hot surface ignitor not positioned

 

 

 

correctly.

 

 

3.

Low voltage to the water heater.

 

 

4.

Electric polarity to unit is incorrect - test and cor-

 

 

 

rect.

 

 

5.

Combustion shut-off device tripped, contact ser-

 

 

 

vice agency.

○ ○ ▼ A B C

 

1.

Turn power to the water heater off for 10 seconds

● ○ ○ ○ ● ●

Problem in the gas valve driver cir-

 

and then back on.

 

cuit.

2.

Replace gas control valve.

 

 

○ ○ ▼ A B C

 

1.

Turn power to the water heater off for 10 seconds

● ○ ● ● ● ○

Problem with the internal circuit.

 

and then back on.

 

 

2.

Replace gas control valve.

○ ○ ▼ A B C

 

1.

Turn power to the water heater off for 10 seconds

● ● ● ● ● ●

Problem with the internal circuit.

 

and then back on.

 

 

2.

Replace gas control valve.

○ ○ ▼ A B C

Flame signal sensed out of

1.

Replace gas control valve.

● ○ ○ ○ ● ○

proper sequence.

 

 

○ ○ ▼ A B C

ECO activated.

1.

Replace gas control valve.

● ○ ○ ● ● ●

 

 

○ ○ ▼ A B C

One of the temperature adjust

1.

Press and release each of the buttons once.

● ○ ● ● ○ ○

buttons stuck closed.

2.

Replace gas control valve.

○ ○ ▼ A B C

Water temperature sensor is either open

1.

Check that all wiring is correct and secure.

● ○ ● ● ○ ●

or short circuited.

2.

Replace gas control valve.

○ ○ ▼ A B C

 

1.

Check for correct wiring to FV sensor.

● ○ ○ ● ○ ●

Unit shuts down.

2.

Check for open circuits to FV sensor.

 

 

3.

Replace FV sensor.

○ ○ ▼ A B C

 

1.

FV sensor detected presence of flammable vapors.

● ○ ○ ○ ○ ●

Unit shuts down and in lockout.

2.

Contact a service agency.

 

 

 

 

Manual backgroundCAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.

Manual backgroundCAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING.

Manual backgroundCAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.

32

Page 32
Image 32
Ruud AP14236 installation instructions Gas Valve LED Codes