BASIC OPTIONS

4.1.3 Registering a Door/Window Sensor

1.To access the menu, press the menu  or menu  button. The display will now read ‘ENTER PIN’.

2.Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). For every digit entered, a * will appear on the display.

3.When the PIN code has been entered correctly, the word ‘INSTALL’ will show up on the display.

4.Press OK.

5.Open your door or window. The console will beep to confirm. The display will read ‘ZONE 1 SET’.

A memory space for a sensor is called a zone. If you have more than 1 sensor installed, it will read e.g. ZONE 2 SET, ZONE 3 SET, … ZONE 30 SET.

You can choose in which zone you want to install the sensor. If you want to install the sensor in zone 3, press 3 on the number pad before executing step 5.

You will find a table in which you can write down which zone contains which sensor at the back of this user manual. We advise you to write down which sensor you have registered in which zone

6.Repeat step 5 for every door/window sensor you wish to register.

7.Press CLEAR to go back to the main menu. Press CLEAR again to quit the menu. To confirm your choice, press 1 for Yes or 2 for No. If you choose Yes, you will quit the menu. If you choose No, you go back to the main menu.

Read chapter 12 for information on replacing the batteries.

4.2 Motion Detector MS90

1. Battery compartment.

2. Control Indicator – Lights up when a signal is transmitted.

3. TEST button.

4. Sensitivity switch 1/2 – In setting 1 the sensor will instantly react to movement, in setting 2 the sensor is less sensitive and will only react after registering two movements.

5. Tamper contact.

5

4.2.1Mounting the Motion Detector MS90 The motion detector works by detecting changes in temperature. Do not mount the detector too close to a heater or air conditioner.

2

4

3

1

The motion detector has a range of 6-10 m and an angle of 90°. Because of the special lens the sensor ‘looks down’. Always mount the MS90 at a height of about 180 cm from the floor and place it in such a way that the detector can cover the area you want to secure. The mounting bracket can be placed at an angle (90°) or directly against the wall.

SAFEGUARD / TOTALGUARD