Fixing outdoor unit

Follow below method to firmly fix the outdoor unit. ffUsing rubber leg

-- Put the rubber leg to the outdoor unit leg. (Refer to illustration on the right.) ffUsing anchor bolt

-- On a flat, rigid ground, use 4 anchor bolt (M10) to fix the unit. (Anchor bolt should be purchased separately.)

-- Select the anchor bolt that is long enough to securely fix the outdoor unit.

❋❋If you need to ensure the outdoor unit from falling, use wires to fix it firmly.

Loosen the 4 screws from the top cover of the outdoor unit.

Put the wire around the screws and fasten the screws.

Fix the wire on the ground.

Anchor bolt fixing dimension 660mm

338mm

ENGLISH

When the outdoor unit is not firmly fixed, it may fall and cause personal injury or property damage.

CAUTION

When the outdoor unit is installed in water-proofed rooftop, fix the wire on the wall.

30cm or more

Outdoor unit

or 30cm more

30cm

Air guide

(Not provided by

or

more

 

manufacturer )

 

 

 

 

more

 

 

or

 

 

60cm

Outdoor

unit leg

50cm

or

more

Rubber leg

20cm or more

 

Spare space for piping

Installation space for outdoor unit

Refer to following examples for wind protection.

ffWhen installing in the street with lots of buildings, install the product parallel to the street. ffIn the places with strong wind, install the product with air outlet facing the wall.

60cm or more

Wall

Strong wind

 

Air outlet

Rooftop

The air intake faces towards the wall

The air outlet faces towards the all

30cm or more

50cm or

 

50cm or

 

more

 

 

 

more

 

 

 

Spare space

 

 

 

 

Spare space

 

for piping

30cm or more

30cm or more

60cm or more

for piping

 

 

 

 

 

39