Installing and connecting the drain hose of the indoor unit

When installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65 mm hole drilled in the wall, check the followings:

Wall

Indoor unit

Drain hose

The drain hose must NOT

The end of the drain hose

The drain hose must not

slant upwards.

must NOT be placed under

be bent.

 

water.

 

atio nall In s05t

5cm less

Keep a clearance of at least

5 cm between the end of the drain hose and the ground.

Ditch

Do not place the end of the drain hose in a hollow.

After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well drained.

Drain hose installation

1.If necessary, connect the 2 meter extension drain hose to the drain hose.

2.If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.

3.Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

• If you do not use the other drain hose hole,

 

block it with a rubber stopper.

 

4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,

 

rotate and insert the drain hose into Extended hose for 40~45 mm. Make sure the

 

two hoses are firmly connected, there is no water leakage.

Drain hose hole

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20 mm .

 

 

 

40~45 mm

20 mm

20 mm

 

 

 

or more

or more

Drain hose

Extension

 

Extension

 

 

 

drain hose

Drain hose

 

 

 

 

drain hose

Vinyl Tape

Foam Insulation

 

 

 

 

English-45

MG_BETTER_A3050_IB&IM_EN_DB68-04070A-00.indd 45

 

 

17/09/2013 11:23:38