Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

Right (A)

Left (B)

Underside_right (C)

Rear_right or left (D)

Direction of pipe

A B

DD

C

• You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.

• If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

1.Disassemble the cover panel as described in page 39~40.

2.Remove the Hanger plate from the indoor unit.

(1) Unscrew 2 screws that fixes the Hanger plate to the indoor unit.

(2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it.

(3) Pull the installation plate to release it completely from the indoor unit.

 

Screw(M4x10)

3.

Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of

 

65 mm so that it slants slightly downwards.

Pipe hole (Ø65 mm)

A

D

B

C

(Unit : mm)

Model

A

B

C

D

18/24

33

110

110

33

 

 

 

 

 

Make sure to drill only one hole after choosing the direction of the pipe.

4. Fix the indoor unit.

If you fix the indoor unit on a wall

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

If you fix the indoor unit on a window frame

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

English-38

Plastic

Anchor

<20 mm

Wall

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 38

2014/4/2 9:49:45

Page 38
Image 38
Samsung AR18HVFSEWKNMG Fixing the installation plate, English-38, Right a Left B Undersideright C Rearright or left D, 110