ERROR CODES

Error Code

General Functions

GAS SENSOR OPEN

In case the value of the gas sensor value is more than 210 during operation/cancellation.

GAS SENSOR SHORT

In case the value of the gas sensor value is less than 6 during operation/cancellation.

GAS SENSOR MAX TIME

In case of gas sensor time is over estimated cook time.

TEMPER SENSOR OPEN

In case the value of the temperature sensor value is more than 250 during operation/cancellation.

TEMPER SENSOR SHORT

In case the value of the temperature sensor is less than 5 during operation/cancellation.

UNFINISHED PREHEAT

In case the oven has not reached the desired temperature although a certain amount of time has passed(Unfinished preheating).

OVER 230 °C DURING OPERATION OF MWO MODE

In case the temperature rises over 230 °C during operation of mwo mode(fire sensed).

WEIGHT SENSOR OPEN

In case the value of the weight sensor value is more than 999 during operation/cancellation.

WEIGHT SENSOR SHORT

In case the value of the weight sensor value is less than 30 during operation/cancellation.

TURN TABLE TAKE OFF

In case of taking off the support tray

DAMPER S/W

In case it fails to sense the DAMPER to open or close for 1 minutes.

62_ troubleshooting and error code

CP1395ST_XSV_DE68-03749Y_EN.indb 62

2011-04-01 ￿￿ 6:12:33

Page 62
Image 62
Samsung CP1395ST/XSV manual Error Codes, Error Code General Functions