SAMSUNG Installation
DCS-816 March 1999
6-6

6.6 ISDN TE (ISDN phone, G4 FAX, etc) (Figure 6-5)

ISDN Terminal Equipment can be connected to any circuit on the BRI card if installed. As
described in section 5.4, the system provides So as well as To application on a port basis. The
system requires MDF connection for a BRI card and the connection can be made through the
champ connector. See Figure 2-3 and refer to section 2.5 (MDF Cabling).
Use two pair twisted wires and connect each ISDN TE to the BRI port of your choice via the
champ connector on the base board.
Note that the DCS Compact BRI card does not provide power to the ISDN terminal equipment.

CONNECTING ISDN TE

25 PAIR CABLE WITH FEMALE CONNECTOR TO THE BASE CHAMP CONNECTOR
FIGURE 6-5
CHAMP CONNECTION
PIN COLOUR CIRCUITS / FUNCTIONS
² CONNECT ISDN TE TO ANY BRI PORT WHEN A
BRI CARD IS INSTALLED
² NO POWER SUPPLY TO ISDN TE
28/ 3 W-GR/ GR-W T/R, TX of 1
st
BRI port
29/ 4 W-BR/ BR-W T/R, RX of 1st BRI port
30/ 5 W-S/ S-W T/R, TX of 2nd BRI port
31/ 6 R-BL/ BL-R T/R, RX of 2nd BRI port
32/ 7 R-O/ O-R T/R, TX of 3rd BRI port (4BRI)
33/ 8 R-GR/ GR-R T/R, RX of 3rd BRI port (4BRI)
34/ 9 R-BR/ BR-R T/R, TX of 4th BRI port (4BRI)
35/10 R-S/ S-R T/R, RX of 4th BRI port (4BRI)
ISDN TEs