Chapter 2. Device setup

Command

No.

Command type

Command

Value range

1

Power control

0x11

0~1

2

Volume control

0x12

0~100

3

Input source control

0x14

-

4

Screen mode control

0x18

-

5

Screen size control

0x19

0~255

6

PIP on/off control

0x3C

0~1

7

Auto adjustment control (PC and

0x3D

0

 

BNC only)

 

 

8

Video wall mode control

0x5C

0~1

9

Safety Lock

0x5D

0~1

10

Video Wall On

0x84

0~1

11

Video Wall User Control

0x89

-

 

 

 

 

All communications take place in hexadecimals. The checksum is calculated by adding up all values except the header. If a checksum adds up to be more than 2 digits as shown below (11+FF+01+01=112), the first digit is removed.

23

E.g. Power On & ID=0

Header

Command

ID

Data

Data 1

Checksum

 

 

 

length

 

 

 

 

 

 

 

 

0xAA

0x11

 

1

"Power"

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Command

ID

Data

Data 1

12

 

 

 

length

 

 

 

 

 

 

 

 

0xAA

0x11

 

1

1

 

To control all devices connected by a serial cable simultaneously irrespective of IDs, set the ID as “0xFE” and transmit commands. Commands will be executed by each device but ACK will not respond.

Power control

Function

A product can be powered on and off using a PC.

Viewing power state (Get Power ON/OFF Status)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

0x11

 

0

 

 

 

 

 

 

Setting power ON/Off (Set Power ON/OFF)

Header

Command

ID

Data

Data

Checksum

 

 

 

length

 

 

 

 

 

 

 

 

0xAA

0x11

 

1

“Power”

 

 

 

 

 

 

 

“Power”: Power code to be set on a product.

1: Power ON

0: Power OFF