Installation

Safety instructions for the installation

This oven may be installed only by an approved electrician. The installer is responsible for connecting the appliance to the mains and in so doing for observing the relevant safety regulations.

Ensure protection from live parts when installing the oven.

The kitchen cabinet in which the oven is built in must satisfy stability requirements as specified in DIN 68930.

Technical specifications

Input voltage/Frequency

230 V ~ 50 Hz

Volume (usable capacity)

66 L

Output rating

max. 3400 W

Net weight

approx. 30.5 kg

Weight with packaging

approx. 35.5 kg

Housing (W x H x D)

595 x 595 x 566 mm

Oven interior (W x H x D)

440 x 365 x 405 mm

Power connection

566

560

595

572

 

595

21

If the appliance is not connected to the mains with a plug, a multi- pole isolator switch (with at least 3 mm contact spacing) must be

provided in order to satisfy safety regulations. The power cable H05 RR-F or H05 VV-F, min.1.5 m, 1.5 ~ 2.5 mm²) must be of sufficient length to be connected to the oven, even if the oven stands on the floor in front of its built-in cabinet. Open the rear connection cover of the oven with a screwdriver and loosen the screws of the cable

clamp before you connect the power lines to the relevant connection

terminals. The oven is earthed via the (

 

 

 

)-terminal. If the oven is

 

connected to the mains with a plug, this

 

 

 

plug must remain accessible

 

 

 

 

 

after the oven is installed. Samsung will take no responsibility for

 

accidents that originate from a missing or faulty earth connection.

 

Installation in the cabinet

 

This is a built-in oven, which needs to be installed into an upper or lower

min. 550

cabinet.

 

Observe minimum distances.

 

Fix oven on both sides using screws

 

After installation, remove the vinyl protective film from the door to the

 

appliance and the protective film from the interior surfaces of the oven.

 

min. 600

 

 

min. 590

 

 

 

max. 600

min. 50

 

 

 

min. 550

min. 550

 

 

 

min. 560

 

 

 

 

min. 50

min. 600

min. 50

 

 

 

min. 560

min. 560

 

 

Airflow

Lower element

Top element