Installing the hob

Installing the hob

Connecting to the mains power supply

Before connecting, check that the nominal voltage of the appliance, that is, the voltage stated on the rating plate, corresponds to the available supply voltage. The rating plate is located on the lower casing of the hob.

WARNING

Shut off power to circuit before connecting wires to circuit.

The heating element voltage is AC 230 V~. The appliance also works perfectly on networks with AC 220 V~ or AC 240 V~. The hob is to be connected to the mains using a device that allows the appliance to be disconnected from the mains at all poles with a contact opening width of at least 3 mm, eg. automatic line protecting cut - out, earth leakage trips or fuse.

WARNING

The cable connections must be made in accordance with regulations and the terminal screws tightened securely.

WARNING

Once the hob is connected to the mains supply, check that all cooking zones are ready for use by briefly switching each on in turn at the maximum setting with suitable cookware.

WARNING

Pay attention (conformity) to phase and neutral allocation of house connection and appliance (connection schemes); otherwise, components can be damaged. Warranty does not cover damage resulting from improper installation.

01

0204 06

0305

L N

01

02

03

05

07

0406

L1 L2 N

01

 

04

 

 

 

 

02

 

 

 

 

05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

 

 

 

 

 

 

 

 

 

 

03

 

 

 

 

06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

N1

 

 

L2

N2

1N~ (32A)

01

220-240 V ~

04

Blue

02

Brown

05

Gray

 

 

 

 

03

Black

06

Green/Yellow

 

 

 

 

2N~ (16A): Separate the 2-phase wires

(L1 and L2) before connection.

01

220-240 V ~

05

Blue

02

380-415 V ~

06

Gray

03

Brown

07

Green/Yellow

04Black

2 x 1N~ (16A): Separate the wires before

connection.

01

220-240 V ~

05

Black

02

Brown

06

Gray

 

 

 

 

03

Blue

07

Green/Yellow

04220-240 V ~

WARNING

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

8  English

WARNING

For correct supply connection, follow the wiring diagram attached near the terminals.

NZ64K5747BK_ET_DG68-00819A-00_EN.indd 8

5/24/2016 4:23:48 PM

Page 36
Image 36