To reattach the fridge doors after you have moved the fridge to its final location, assemble the parts in reverse order.
1.The Water Line must be fully inserted into the center of the transparent coupler (Type A) or the Guide Lines (Type B) to prevent water leakage from the dispenser.
Type A | Type B |
| Dispenser |
Center of Transparent coupler | The Guide Lines |
|
3.Press the locking tab and separate the Wire Connector.
When reassembling it, be sure to connect CAUTION the wire harness.
If it is not connected, the Flex Room does not work.
4.Remove 1 hex head bolt from each side with a socket wrench (10 mm).