PATTERN
This is a replay function so that the MANUAL functions such as PAN, TILT, ZOOM, and FOCUS are played for 30 seconds.
ALARM SET
It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.
** MAIN MENU **
CAMERA...
➞
Press
(AUTO MODE)
AUTO PAN ...
PATTERN SET 1...
It recognizes the ALARM signal input as an ALARM signal when it continnes more than 150ms for a time and each ALARM movement time is decided depending on it's correspondence to the DWELL TIME of the PRESET and PATTERN connected.
VIDEO SET...
PRESET...
AUTO MODE...
ALARM SET...
OTHER SET...
[Enter]
RET
PATTERN1 SET
** MAIN MENU **
CAMERA...
VIDEO SET...
PRESET ...
AUTO MODE...
ALARM SET...
OTHER SET...
➞
Press
[Enter]
( ALARM SET)
ALARM PRIORITY SET.. ALARM IN SET.. ALARM OUT SET.. ALARM PATTERN SET.. AUX OUT CONTROL..
RET
➞
Press
[Enter]
ALARM PRIORITY SET
Sets the priority of the 4 ALARM inputs and corresponds to priority.The priority of the DEFAULT is ALARM1: 1, ALARM2: 2, ALARM 3: 3, ALARM: 4, MOTION: 5.If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority.While the ALARM is working, it cannot detect MOTION.
ALARM PRIORITY
ALARM1 1
ALARM2 2
ALARM3 3
ALARM4 4
EXIT QUIT
PATTERN can be set to 3. Choose 1, 2, or 3 with the left or right key in the "PATTERN SET" and press [ENTER] to get into the PATTERN set up screen.
From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the MANUAL movements and after 30 seconds it will return to a higher menu.
If you want to finish set up before the
ALARM IN SET
Set the TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.
ALARM IN
ALARM1 NO ALARM2 NC ALARM3 NO ALARM4 NC
EXIT QUIT