Setting RS-422A/RS-485 termination

As it is shown in the structure map, when Controller and RS-422A/RS-485 is connected it should be terminated according to the Cable feature of impedance on the each end of the transmitting line to transfer the signals in long distance by controlling the reflection of the signals to the lowest.

Division

n < 128

Termination

SW1-ON

<RS-485 Half Duplex Organization>

Termination: using numbers 1 and 2 PIN, turn to ON and it will be terminated.

n < 128

SWITCH SETTING

Receiver Address

SW500-1 SW500-2

SW500-3 SW500-4 SW500-5 SW500-6 SW500-7

SW500-8

0

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

12

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

13

ON

OFF

ON

ON

ON

OFF

OFF

OFF

14

OFF

ON

ON

ON

ON

OFF

OFF

OFF

15

ON

ON

ON

ON

ON

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

Division

Division SW1-ON SW2-ON

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

39

ON

ON

ON

OFF

OFF

ON

OFF

OFF

40

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

41

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

42

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

43

ON

ON

OFF

ON

OFF

ON

OFF

OFF

<RS-422A/RS-485 Full Duplex Organization>

44

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

45

ON

OFF

ON

ON

OFF

ON

OFF

OFF

46

OFF

ON

ON

ON

OFF

ON

OFF

OFF

47

ON

ON

ON

ON

OFF

ON

OFF

OFF

48

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

49

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

50

OFF

ON

OFF

OFF

ON

ON

OFF

OFF

51

ON

ON

OFF

OFF

ON

ON

OFF

OFF

52

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

53

ON

OFF

ON

OFF

ON

ON

OFF

OFF

54

OFF

ON

ON

OFF

ON

ON

OFF

OFF

55

ON

ON

ON

OFF

ON

ON

OFF

OFF

1-13

1-14

Page 8
Image 8
Samsung SCC-641P, SCC-641N manual Setting RS-422A/RS-485 termination, Termination