Samsung SCC-C6323N Installation, DIP Switch Setup, Camera ID Setup, Communication Protocol Setup

Models: SCC-C6325P SCC-C6323N SCC-C7325P SCC-C7325N SCC-C6323P

1 215
Download 215 pages 58.42 Kb
Page 13
Image 13

Installation

DIP SWITCH SETUP

Before you install the camera, you should set the DIP switches to confi gure the camera ID, Baud rate, and communication protocol.

Protocol

Buad Rate

Auto Select

 

RS-485

Terminate

ID Setting (1~255)

Camera ID Setup

ID number of camera is set using binary number. The example is shown bellow.

Pin

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

ID Value

1

2

4

8

16

32

64

128

 

 

 

 

 

 

 

 

 

ex) ID=5

on

off

on

off

off

off

off

off

ex) ID=10

off

on

off

on

off

off

off

off

 

 

 

 

 

 

 

 

 

The range of ID is 0~255. Factory default of Camera ID is 1.

If you want to control a certain camera, you must match the camera ID with Cam ID setting of DVR or Controller.

Communication Protocol Setup

ON ON

1 2 3 4 5 6 7 8

Select the appropriate Protocol with DIP switch combination.

 

Switch State

 

Protocol

 

 

 

 

Pin1

Pin2

Pin3

Pin4

 

 

 

 

 

 

OFF

OFF

OFF

OFF

Auto Protocol

ON

OFF

OFF

OFF

Pelco-D

OFF

ON

OFF

OFF

Pelco-P

ON

ON

OFF

OFF

Samsung

• If you set the protocol as Auto Protocol, camera

will automatically recognize the kind of Protocol.

• Auto Protocol supports Pelco-D and Samsung Protocol.

• If you want to control using DVR or system

 

keyboard, their protocol must be identical to

camera. Otherwise, you can not control the camera.

• If you changed camera protocol by changing DIP S/W,

the change will be effective after you reboot the camera.

• Factory default of protocol is “Auto Protocol

Communication Baud rate Setup

ENG

 

 

 

 

 

 

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

Select the appropriate Baud rate with DIP switch combination.

 

Switch State

 

Protocol

 

 

 

 

 

Pin5

 

Pin6

 

Pin7

 

 

 

 

 

 

 

OFF

 

OFF

 

OFF

2400 BPS

ON

 

OFF

 

OFF

4800 BPS

OFF

 

ON

 

OFF

9600 BPS

 

 

 

 

 

 

ON

 

ON

 

OFF

19200 BPS

 

 

 

 

 

 

OFF

 

OFF

 

ON

38400 BPS

 

 

 

 

 

 

• Factory default of Baud rate is “9600 BPS”